Chapter 7 Measuring Waveform
7-40
7.10.2 Adjusting Vertical-axis of Screen
To adjust voltage or optical power at center of vertical axis
1. Touch [Offset] at Amplitude on the left side of the waveform display
area.
The rotary knob icon is displayed in the button.
2. Input the power voltage or optical power at the screen center position
using the rotary knob.
3. When using the trace A, the input value is displayed at the left center
of the waveform display area.
When using the trace B, the input value is displayed at the right
center of the waveform display area.
To adjust voltage or optical power per scale:
1. Touch [Scale] at Amplitude in the right side of the waveform display
area.
The rotary knob icon is displayed in the button.
2. Input the voltage or optical power per scale using the rotary knob.
3. When using the trace A, the input value is displayed at the left upper
corner of the waveform display area.
When using the trace B, the input value is displayed at the right
upper corner of the waveform display area.
The vertical-axis can also be adjusted by directly entering the value in the
Amplitude dialog box.
1. Touch
[Amplitude].
2. Touch the Offset text box.
3. Input the voltage or optical power at the screen center position.
4. Touch the Scale text box.
5. Input the voltage or optical power per scale.
Summary of Contents for BERTWave MP2100B
Page 24: ...xxiv...
Page 96: ...Chapter 2 Before Use 2 42...
Page 112: ...Chapter 3 Connecting with DUT 3 16...
Page 250: ...Chapter 7 Measuring Waveform 7 64 Figure 7 12 1 Marker Display...
Page 262: ...Chapter 7 Measuring Waveform 7 76...
Page 276: ...Chapter 8 Operating Optical Interface 8 14...
Page 304: ...Chapter 9 Performance Test 9 28...
Page 320: ...Chapter 10 Maintenance 10 16...
Page 374: ...Appendix E Performance Test Record Form E 10...
Page 382: ...Index Index 6...