106 • Schlage • ENGAGE Managed Property User's Guide
Device Defaults
Web Application
NDE80 and NDEB
Fig. 8.106: NDE Default Settings
Table 8.13 NDE80 and NEDB Device Property Default Settings
Setting
Description
Beeper Enabled
• ON: the lock beeper will sound to provide device status.
• OFF: the lock beeper will remain silent.
Relock Delay
(seconds)
When a valid credential is presented, the locking device unlocks and then relocks.
Delayed relocks are from 1 – 30 seconds.
ADA Relock Delay
(seconds)
Enables ADA operation to allow additional time to access doors. Delayed relocks
are from 1 – 30 seconds.
Propped Door Delay
(seconds)
Reports and records a Propped Door Audit after a specified time. Delayed relocks
are from 1 – 255 seconds.
Power Fail Mode
Defines what the lock should do when entering Critical Battery Mode.
• Secure : Locked
• Passage: Unlocked
• AS IS: no change
Mobile Credential
• OFF: Mobile Credential use is disabled.
• ON: lock will accept Mobile Credential access and the following options are
available.
Communication
Range
Enables the Schlage Mobile Credential application to find locks from short or longer
distances.
Note:
Î
This is a PACS only feature. This setting has no effect on ENGAGE
accounts.
Performance
Affects how often the device scans for a Mobile Credential.
• Normal: Default
• Max: Highly recommended for best user experience and quicker device unlocking
when using Mobile Credentials. Reduces battery life by a few months as the
device scans more frequently.