143 • Schlage • ENGAGE Managed Property User's Guide
NDE80 and NDEB ENGAGE Devices
Installation and Commissioning
With the DPS door drill preparation accomplished and the NDEB inside escutcheon properly installed,
the DPS may be fully installed.
• Feed the wires through the interconnected drill
holes to bring the wires to the interior side of the
door
• Fully seat the DPS magnet into the door edge
• Route the wires under tabs as shown below (2),
ensuring that any excess wires are tucked into the
door (3) and out of harms’ way.
• Securely attach DPS connector (1) to the NDEB
printed circuit board.
Factory Default Reset Overview
A Factory Default Reset (FDR) will return the NDE80
or NDEB to its original settings as shipped from the
factory. Additionally, the following will occur.
• The device to beep once when the inside lever is
turned.
• Removes any non-default device settings, deletes
any construction access credentials.
• Does NOT have any effect on the firmware currently
on the lock.
• Does NOT remove the NDE80 or NDEB from your
ENGAGE account.
• May allow construction mode to be entered again.
Perform an FDR
1. Remove the NDE80 or NDEB battery
cover.
2. Press and HOLD the FDR button for 5
seconds. The lock beeps and blinks 2
times.
3. Turn the inside lever 3 times within 20
seconds.
a. The lock blinks RED and beeps on
each lever turn; then provides 2
GREEN flashes and beeps to indicate
success.
Verify Success of the FDR
4. Turn the inside lever; it will beep once to indicate success.
a. The lock now “advertises” via Bluetooth communication and can be seen in the Select an
NDE/NDEB screen as available for commissioning in the ENGAGE Mobile application.
b. When “Block Construction Mode” has been disabled, prior to the FDR, a new Master
Construction Credential can now be created.
Note:
Î
Bluetooth (BLE) communication requires the lock battery cover to be properly installed. A
loose battery cover may not allow the lock to “Advertise” when connecting.
Construction Access Mode Overview
Construction Access Mode provides temporary access prior to commissioning the device and requires
an electronic credential (see the Master Programming Credential section below).
Fig. 11.44:
NDEB DPS wire routing
The ENGAGE Mobile
Application Advanced
settings may be used
to “Block”
Construction Mode
after commissioning.
When “Blocked”,
Construction Mode
cannot be entered
again after FDR. The
Master Credential
enrollment is denied.
To enable
Construction Mode
again, use the
ENGAGE Mobile
Application Advanced
menu to “Unblock”
the Construction
Mode setting and
SAVE. An FDR is
required to begin
again.
Fig. 11.45: NDE80 or NDEB FDR Button