152 • Schlage • ENGAGE Managed Property User's Guide
CTE Controller with Multi-Technology Readers
Installation and Commissioning
Perform an FDR
1. Remove
the lid.
2. Press
and
HOLD
the
FDR
button for 5 seconds,
then
release
.
• CTE will beep 2 times and the STATUS LED will
blink
GREEN
2 times at the end of 5 seconds.
3. Press
the
Schlage
button
3 times; there is one
beep for each button press.
• CTE will beep once and the STATUS LED will
light
GREEN
.
Verify Success of the FDR
The CTE STATUS LED will be solid
RED
and the
MODE LED for Factory Default will be solid
GREEN
.
Construction Mode Overview
The Construction Mode is used to allow access
before the CTE controller is commissioned and for
testing purposes.
Construction Mode:
The Construction Mode is
enabled by default and after a Factory Default Reset (FDR).
• Construction Mode provides NORMAL Credential function and the CTE always automatically
relocks after momentary access is granted.
• The CTE will remain in Construction Mode until the mode is cancelled by performing an FDR or
Commissioning into an ENGAGE account.
• No access audits are captured while the CTE is in Construction Mode.
Master Construction Credential:
The Master Construction Credential is used to add additional
User
Constructions Credentials to each installed CTE.
• The Master Construction Credential will not grant access through a door.
• The Master Construction Credential
must
be programmed before programming construction access
mode with user credentials.
• The Master Construction Credential is
ONLY
used to add additional User Construction Credentials.
• Use the same Master Construction Credential for all the controllers in the facility.
• If the Master Construction Credential is lost or destroyed, no additional user construction
credentials can be added to the CTE.
Cancel Construction Mode:
To cancel the Construction Mode and to remove all credentials, perform
a factory default reset (FDR
)
or commissioning.
• When Construction Mode is cancelled, the Master Construction Credential and all other added User
Construction Credentials will no longer function.
• To enter the Construction Access Mode again, a new Master programming Credential must be
created, and new User Access Construction credentials will need to be re-enrolled.
Create a Master Construction Credential
The CTE requires a Master Construction Credential that is used to add additional User Access
Construction Credentials to each installed CTE.
1. Begin with a new CTE or after a successful FDR.
2. Remove
lid.
3. Press
and
hold
the
Schlage button
for 5 seconds;
• CTE MODE indicator switch for Construction will be illuminated.
4. Present
a credential to the reader within 20 seconds of releasing the
Schlage button.
5. The CTE STATUS LED and reader’s LED will blink
GREEN
5 times
indicating success
.
• The credential is now the Master Construction Credential.
Fig. 11.60: CTE FDR and SCHLAGE Switches
Fig. 11.61: FDR Mode
Fig. 11.62: Construction
Mode