8-572
Voltage failure
Modify the primary breaker voltage to the specified voltage 200V(+10% to
15%).
Module
failure(contactor)
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, replace the contactor.
Module
failure(converter)
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, replace the SERVOPACK.
EAXA board failure
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, replace the EAXA board. Save the CMOS.BIN
before replacing the board to be safe.
4867
OVERLOAD
WARNING(SERVO
2)
Module
failure(SERVOPACK
)
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, replace the SERVOPACK.
Setting error
Check the settings for manipulator motion condition (influence by external
force, load condition).
Connection failure
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, check the connection and inserting state of the
following cables and connectors.
·The SERVOPACK motor power line connector
·The power cable connection of the manipulator cable.
4868
REGENERATIVE
OVERLOAD
WARN(SV2)
Module
failure(SERVOPACK
)
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, replace the SERVOPACK.
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy