8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-74
YIF board failure
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YIF01 board, and then load
the CMOS.BIN saved before alarm occurred.
0350
VERIFY
ERROR(DEVICEN
ET ALLOC FL)
0
The station No. specified by the
DeviceNet allocation file1 is
incorrect (the station No. is out of
the allowable range, or the
specified station board is not the
DeviceNet master).
Setting error
(1)Check the following settings.
[XFB01 board]
· The settings of the objective DeviceNet allocation file
· The I/O module settings of the objective DeviceNet board in maintenance
mode
· The DeviceNet allocation of the I/O module in maintenance mode
YCP01 board failure (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the YCP01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YCP01 board, and then
remove the CF from the failure YCP01 board to insert it into the new YCP01
board.
YIF board failure
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YIF01 board, and then load
the CMOS.BIN saved before alarm occurred.
1
The MAC_ID specified by the
DeviceNet allocation file1 is not
consistent with the MAC_ID of the
specified station board.
Setting error
(1)Check the following settings.
[XFB01 board]
· The settings of the objective DeviceNet allocation file
· The I/O module settings of the objective DeviceNet board in maintenance
mode
· The DeviceNet allocation of the I/O module in maintenance mode
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy