8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-220
2
The specified axis speed control
function was executed for the axis
which the deceleration stop
function was enabled.
Specified axis speed control
function cannot be used for the
axis which the deceleration stop
function was enabled.
Setting error
Check the JOB.
1659
MOTOR GUN
CHANGE PG PWR
ON ERR(SV)
Setting error
Check if the PICK instruction was executed again for the axis where
executed the PICK instruction in the gun change system.
1660
MOTOR GUN
CHANGE SV ON
ERR(SV)
Setting error
Check if the PICK instruction was executed again for the axis where
executed the PICK instruction in the gun change system.
1661
MOTOR GUN
COND. FILE NO.
ERR(SV)
Setting error
Check the JOB.
File setting error
Check the gun condition file.
1662
MOTOR GUN
PRESS FILE NO.
ERR(SV)
Setting error
Check the JOB.
File setting error
Check the gun condition file.
1663
WRONG MOTOR
GUN PRESS AXIS
(SV)
Setting error
Check the JOB.
File setting error
Check the gun condition file.
1664
MICRO PRG
EXECUTE TIME
OVER(SV)
EAXA board failure
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, replace the EAXA board. Save the CMOS.BIN
before replace the board to be safe.
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy
Содержание MOTOMAN DX100