8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-298
4
The converted job cannot be
edited.
Setting error
(1)Check the following settings.
·The prohibit status of converted job
If the converted job is protected from editing, it cannot be edited.
5
The memory area for job area is
insufficient.
Software operation
error occurred
(1)Reset the alarm.
(2)If the error occurs again, delete unused jobs.
(3)If the error occurs again after the previous measures were executed,
initialize the job file in the maintenance mode, and then load the saved job
file. In that case, delete the unused jobs.
(4)If the error occurs again though the previous measures were executed,
save the CMOS.BIN in maintenance mode, and then contact your Yaskawa
representative about occurrence status (operating procedure).
6
The source job is not exist.
Setting error
(1)Check the following settings.
·Presence of the specified source job
The job which does not exist cannot be set to the source job.
7
The memory area for position data
of the job is insufficient.
Software operation
error occurred
(1)Reset the alarm.
(2)when the error occurs again, if there is an unnecessary teaching position,
delete it.
(3)If the error occurs again after the previous measures were executed,
initialize the job file in the maintenance mode, and then load the saved job
file. In that case, delete the unused jobs.
(4)If the error occurs again though the previous measures were executed,
save the CMOS.BIN in maintenance mode, and then contact your Yaskawa
representative about occurrence status (operating procedure).
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy
Содержание MOTOMAN DX100