8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-452
6
CPU2 detected an inconsistency
of full speed test signal.
Connection failure
(1)Reset the alarm.
(2)If the alarm occurs again, check the followings.
·Wiring confirmation of YSU unit (CN216 connector) and pin numbers 23, 24,
25, and 26 of MXT terminal block
8
CPU2 detected an inconsistency
of overrun 1 signal.
Connection failure
(1)Reset the alarm.
(2)If the alarm occurs again, check the followings.
·Wiring confirmation of pin numbers 1, 2, 3, and 4 of YSU unit (CN203
connector)
9
CPU2 detected an inconsistency
of universal input zero signal.
Connection failure
(1)Reset the alarm.
(2)If the alarm occurs again, check the followings.
·Wiring confirmation of YSU unit (CN216 connector) and pin numbers 1, 2, 3,
and 4 of MXT terminal block
10
CPU2 detected an inconsistency
of universal input 1 signal.
Connection failure
(1)Reset the alarm.
(2)If the alarm occurs again, check the followings.
·Wiring confirmation of YSU unit (CN216 connector) and pin numbers 5, 6, 7,
and 8 of MXT terminal block
14
CPU2 detected an inconsistency
of mode zero signal in the
programming pendant.
Connection failure
(1)Reset the alarm.
(2)If the alarm occurs again, check the followings.
·Connected confirmation of wiring for pin numbers B6 of YSU unit (CN209
connector) and programming pendant
Hardware failure
(1)Reset the alarm.
(2)If the alarm occurs again after confirming the connection, execute the
following contents. Save the CMOS.BIN before replacing the YSU unit to be
safe.
·Replacement of programming pendant
·Replacement of programming pendant
·Replacement of YSU unit
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy