8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-430
Connection failure
(1)Reset the alarm.
(2)If the alarm occurs again, check the followings.
·Confirmation of wiring for pin numbers A3, A4, B3, and B4 of YSU unit
(CN209 connector) and connector of programming pendant
Hardware failure
(1)Reset the alarm.
(2)If the alarm occurs again after confirming the connection, execute the
following contents. Save the CMOS.BIN before replacing the YSU unit to be
safe.
·Replacement of programming pendant
·Replacement of programming pendant
·Replacement of YSU unit
4384
M-SAFETY
SIGNAL
ERROR(CPU1)
0
CPU1 detected an inconsistency
of emergency stop signal in the
programming pendant.
Connection failure
(1)Reset the alarm.
(2)If the alarm occurs again, check the followings.
·Confirmation of wiring for pin numbers A3, A4, B3, and B4 of YSU unit
(CN209 connector) and connector of programming pendant
Hardware failure
(1)Reset the alarm.
(2)If the alarm occurs again after confirming the connection, execute the
following contents. Save the CMOS.BIN before replacing the YSU unit to be
safe.
·Replacement of programming pendant
·Replacement of programming pendant
·Replacement of YSU unit
·Replacement of the emergency stop button on the programming pendant
and the cable that connects to the YSU unit
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy