8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-86
YIF board failure
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YIF01 board, and then load
the CMOS.BIN saved before alarm occurred.
53
An error occurred during startup
sequence processing with the
servo CPU of 4th servo board, and
the system did not startup
normally.
Setting error
(1)Check the following settings.
· Control group settings in maintenance mode
· The EAXA board rotary switch setting (3) of the corresponding node
number (SV#4)
Connection failure
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, check the connection and insertion of the
following cables and connectors.
· The cable of EAXA board CN509
· The cable of EAXA board connector CN515/516
· The PCI connector of the YIF01 board
· The cable of YIF board connector CN113
EAXA board failure
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the EAXA board. Save the CMOS.BIN
before replace the board to be safe.
YIF board failure
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YIF01 board, and then load
the CMOS.BIN saved before alarm occurred.
54
An error occurred during startup
sequence processing with the
servo CPU of 5th servo board, and
the system did not startup
normally.
Setting error
(1)Check the following settings.
· Control group settings in maintenance mode
· The EAXA board rotary switch setting (4) of the corresponding node
number (SV#5)
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy