8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-342
99
A job data in the memory was
destroyed.
Software operation
error occurred
(1)Reset the alarm.
(2)If the error occurs again, delete the job where the alarm occurred.
(3)If the error occurs again after the previous measures were executed,
initialize the job file in the maintenance mode, and then load the saved job
file.
(4)If the error occurs again though the previous measures were executed,
save the CMOS.BIN in maintenance mode, and then contact your Yaskawa
representative about occurrence status (operating procedure).
4203
SYSTEM
ERROR(POSITION
DATA)
-1
The memory area for position data
is lacking at the initialization of the
position data control process.
Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
YIF board failure
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YIF01 board, and then load
the CMOS.BIN saved before alarm occurred.
YCP01 board failure (1)Reset the alarm, and then try again.
(2)If the alarm occurs again, replace the YCP01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YCP01 board, and then
insert the CF card which inserted original YCP01 board into the new YCP01
board.
-2
The number of axes for all the
control groups is zero at the
initialization of the position data
control process.
Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy
Содержание MOTOMAN DX100