8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-313
3
An error occurred in connection
detecting process of TCP server of
the Ethernet function.
Software operation
error occurred
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
YCP01 board failure (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the YCP01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YCP01 board, and then
insert the CF card which inserted original YCP01 board into the new YCP01
board.
4
An error occurred in the
connection detection checking
process of TCP server of the
Ethernet function.
Software operation
error occurred
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
YCP01 board failure (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the YCP01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YCP01 board, and then
insert the CF card which inserted original YCP01 board into the new YCP01
board.
4135
TOYOPUC RUN
STOP
0
Setting error
(1)Check the following settings.
·Use the PCwin, etc. to run the TOYOPUC.
4136
TOYOPUC MAJOR
ERROR
0
The PCI bus state of the
TOYOPUC turns to "ER".
Setting error
(1)Check the following settings.
· OFF/ON status of the remote
·OFF/ON status of the power supply
Turn OFF and back ON the remote or power supply.
4137
WRONG
EXECUTION OF
SETUALM INST
1
Alarm code specification error
Setting error
(1)Check the following settings.
·Alarm code
Specify the alarm in the range 8000 to 8999.
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy