8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-142
1104
SYSTEM
ERROR(CIO)
Sub Code
1000_0000: I/O module setting
error
Connection failure
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, check the connection and inserting state of the
following cables and connectors.
·CN300 communications connector of YIU unit
·CN304 power supply connector
·Cable of the YIU unit and the expanded I/O board
Setting error
(1)Turn the power OFF then back ON.
(2)If the error occurs again, set the I/O module again in maintenance mode.
(3)If the error occurs again though the previous measures were executed,
save the CMOS.BIN in maintenance mode, and then contact your Yaskawa
representative about occurrence status (operating procedure).
YCP01 board failure (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the YCP01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YCP01 board, and then
remove the CF from the failure YCP01 board to insert it into the new YCP01
board.
1105
SYSTEM
ERROR(SERVO)
0
No processing corresponds to the
command code sent from
MOTION section.
Software operation
error occurred
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
EAXA board failure
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, replace the EAXA board. Save the CMOS.BIN
before replace the board to be safe.
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy
Содержание MOTOMAN DX100
Страница 728: ...DX100 Index Index v X XYZ coordinate data 8 3 ...