8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-263
4024
MEMORY
ERR(WRIST WEAV
AMP FILE)
1
Data error
(1)Reset the alarm.
(2)If the alarm occurs again, initialize the wrist weaving amplitude file in
maintenance mode, and then load the wrist weaving amplitude file saved in
the external memory device.
YCP01 board failure (1)Reset the alarm.
(2)If the alarm occurs again, replace the YCP01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YCP01 board, and then
insert the CF card which inserted original YCP01 board into the new YCP01
board.
YIF board failure
(1)Reset the alarm.
(2)If the alarm occurs again, replace the YIF board. Save the CMOS.BIN
before replace the board to be safe. Replace the YIF board, and then load
the CMOS.BIN saved before alarm occurred.
4025
MEMORY
ERROR(INTERRU
PT JOB FILE)
Data error
(1)Reset the alarm.
(2)If the alarm occurs again, initialize the interrupt job file in maintenance
mode, and then load the interrupt job file saved in the external memory
device.
YCP01 board failure (1)Reset the alarm.
(2)If the alarm occurs again, replace the YCP01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YCP01 board, and then
insert the CF card which inserted original YCP01 board into the new YCP01
board.
YIF board failure
(1)Reset the alarm.
(2)If the alarm occurs again, replace the YIF board. Save the CMOS.BIN
before replace the board to be safe. Replace the YIF board, and then load
the CMOS.BIN saved before alarm occurred.
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy
Содержание MOTOMAN DX100