8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-425
EAXA board failure
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, replace the EAXA board. Save the CMOS.BIN
before replacing the board to be safe.
4354
FILE NO.
ERROR(SHOCK
LEVEL)
Sub Code: File number
Setting error
Do not use the collision detection file for exclusive use for the SVSPOT with
the SHCKSET instruction.
4355
EXTERNAL PRES
DETECT(SERVOF
LOAT)
Setting error
Check the settings for jobs.
4356
ARM CTRL
PARAMETER
ERR(OBSERVER)
Setting error
Check the settings for jobs.
4357
IMPOSSIBLE
SRCH(EQUALIZE
TEACH)
Setting error
Check the settings for jobs.
4358
DUPLICATED
PRESS ERROR
Setting error
End the current pressuring operation, and then execute the pressuring
instruction.
4359
CONVERTER
ERROR
Sub Code: Signifies the physical
No. of converter in which the alarm
occurred
Connection failure
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, check the connection and inserting state of the
following cables and connectors.
·EAXA01-CN507,510
·EAXB01-CN08
·Converter CN551,553
Module
failure(converter)
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, replace the SERVOPACK.
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy
Содержание MOTOMAN DX100