5
Replacing Parts
DX100
5.1
Replacing DX100 Parts
5-3
5.1.1.1
Replacing the Battery
Replace the battery immediately if a battery alarm occurs. Replace the
battery within two hours after the breaker turns OFF.
(The battery alarms appear on the programing pendant display.)
Replacement Procedure
1. Remove the battery connector on the robot I/F circuit board and fixing
screws below the battery to remove the battery.
2. Mount a new battery on the robot I/F circuit board and connect the
connector (CN110/BAT).
5.1.1.2
Replacing the Control Circuit Board (JANCD-YCP01-E)
Turn OFF the power before replacing a circuit board.
Replacement Procedure
1. Disconnect all cables connected to the circuit board.
2. Remove screws fixing the circuit board from upper and lower side.
(one part at each side)
3. Pull out the circuit board from the rack.
4. Remove the Compact Flash from the removed circuit board and insert
the Compact Flash into a new circuit board.
5. Mount the new circuit board to the rack.
6. Tighten upper and lower screws.
7. Connect all disconnected cables.
NOTE
Although the CMOS memory is backed up by super capaci-
tor, the battery must be replaced as soon as the battery
alarm occurs.
The job data and other data may be lost if the battery alarm
occurs and the breaker is turned OFF for more than 2
hours.