8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-455
YSU Unit or
connection cable
failure
(1)Reset the alarm.
(2)If the alarm occurs again after replacement the contactor or relay that
drives contactor, execute the following contents. Save the CMOS.BIN before
replacing the YSU unit to be safe.
·Replacement of YSU unit
·Replacement of connection cable
22
CPU2 detected an inconsistency
of servo ON 4 signal (SFRDY4).
YSU unit failure
(1)Reset the alarm.
(2)If the alarm occurs again, replace the YSU unit. Save the CMOS.BIN
before replacing the YSU unit to be safe.
23
CPU2 detected an inconsistency
of contactor 4 signal (KMMB4).
Connection failure
(1)Reset the alarm.
(2)If the alarm occurs again, check the followings.
·Wiring confirmation of pin numbers 27, 28, 29, and 30 of YSU unit (CN215
connector)
Contactor failure
(1)Reset the alarm.
(2)If the alarm occurs again after confirming the connection, execute the
following contents.
·Replacement the connected contactor or relay that drives contactor
YSU Unit or
connection cable
failure
(1)Reset the alarm.
(2)If the alarm occurs again after replacement the contactor or relay that
drives contactor, execute the following contents. Save the CMOS.BIN before
replacing the YSU unit to be safe.
·Replacement of YSU unit
·Replacement of connection cable
24
CPU2 detected an inconsistency
of contactor 1 enable signal.
Connection failure
(1)Reset the alarm.
(2)If the alarm occurs again, check the followings.
·Wiring confirmation of pin numbers 1, 2, 3, and 4 of YSU unit (CN211
connector)
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy
Содержание MOTOMAN DX100