8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-180
EAXA board failure
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, replace the EAXA board. Save the CMOS.BIN
before replace the board to be safe.
1306
AMPLIFIER TYPE
MISMATCH
Sub Code: Signifies the axis in
which the alarm occurred
Setting error
(1)Check the following settings.
· Check the current capacity of the amplifier before/after replacement by the
model described in board.
· When the external axis is mounted, check if there is no difference between
the amplifier selected at configuration and the amplifier that is actually
mounted.
Reference parameter: after SVPxG232
Connection failure
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, check the connection and insertion of the
following cables and connectors.
·EAXA01-CN517
· YSU01-CN202
Module
failure(amplifier)
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, replace the amplifier.
EAXA board failure
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, replace the EAXA board. Save the CMOS.BIN
before replace the board to be safe.
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy