8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-205
Module
failure(SERVOPACK
)
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, replace the SERVOPACK.
1543
MODULE
ERROR(SERVO2)
Module
failure(SERVOPACK
)
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, replace the SERVOPACK.
1544
FC SERIAL
ENCODE SCALE
ERR(SV2)
Module failure(serial
conversion unit)
Replace the serial conversion unit.
Module
failure(encoder)
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, replace the SERVOPACK.
1545
FC SERIAL
CONVERT COMM
ERR(SV2)
Connection failure
Check the insertion and connection of the followings.
· Serial conversion unit
· Cable between SERVOPACKs.
Noise interference
Check the noise source and take countermeasures to reduce the noise.
Module failure(serial
conversion unit)
Replace the serial conversion unit.
Module
failure(SERVOPACK
)
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, replace the SERVOPACK.
1546
COMMUNICATION
SET
ERR(ML2)(SV2)
The transmission cycle setting of
MECHATROLINK communication
is incorrect.
Setting error
Check the transmission cycle setting of MECHATROLINK communication.
1547
CURRENT
FEEDBACK
ERROR
Ground fault
Check if a ground fault has not occurred in the U-, V-, and W-phase of motor
power line, or short circuit has not occurred between these phases.
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy
Содержание MOTOMAN DX100