8-465
50
CPU2 detected an error of enable
switch signal between YSU unit by
the self-diagnostic check.
YSU unit failure
(1)Reset the alarm.
(2)If the alarm occurs again, replace the YSU unit. Save the CMOS.BIN
before replacing the YSU unit to be safe.
52
CPU2 detected an error of speed
mode zero signal between YSU
unit by the self-diagnostic check.
YSU unit failure
(1)Reset the alarm.
(2)If the alarm occurs again, replace the YSU unit. Save the CMOS.BIN
before replacing the YSU unit to be safe.
54
CPU2 detected an error of speed
mode 1 signal between YSU unit
by the self-diagnostic check.
YSU unit failure
(1)Reset the alarm.
(2)If the alarm occurs again, replace the YSU unit. Save the CMOS.BIN
before replacing the YSU unit to be safe.
58
CPU2 detected an error of error
signal between function safety unit
by the self-diagnostic check.
YSU unit failure
(1)Reset the alarm.
(2)If the alarm occurs again, replace the YSU unit. Save the CMOS.BIN
before replacing the YSU unit to be safe.
60
CPU2 detected an error of speed
mode zero feedback ready signal
between function safety unit by the
self-diagnostic check.
YSU unit failure
(1)Reset the alarm.
(2)If the alarm occurs again, replace the YSU unit. Save the CMOS.BIN
before replacing the YSU unit to be safe.
62
CPU2 detected an error of speed
mode 1 feedback ready signal
between function safety unit by the
self-diagnostic check.
YSU unit failure
(1)Reset the alarm.
(2)If the alarm occurs again, replace the YSU unit. Save the CMOS.BIN
before replacing the YSU unit to be safe.
4393
M-SAFETY
OUTPUT CHECK
ERROR CPU2
49
CPU2 detected no change of the
feedback signal within a certain
time period in link signal between
YSU units.
Connection failure
(1)Reset the alarm.
(2)If the alarm occurs again, check the followings.
·Connector connection confirmation of YSU unit (CN205/CN206)
Rotary switch setting
error
(1)Reset the alarm.
(2)If the alarm occurs again after confirming the connection, execute the
following contents.
·Set rotary switch (S1) settings of the master control YSU unit to "1"; set
rotary switch (S1) settings of slave control YSU unit to "2".
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy