8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-471
4
The prereading processing in the
arithmetic processing section has
not completed.
Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
5
The arithmetic processing section
is not ready for the timer follow-up
of the conveyor tracking function.
Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
6
The prereading processing in the
arithmetic processing section has
not completed when specifying the
target position.
Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
4401
SEQUENCE TASK
CONTR ERROR
1
Unused A_BANK does not exist in
the prereading processing of move
instruction.
Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
2
Unused bank priority does not
exist in the prereading processing
of move instruction.
Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
5
A_BANK pointer is not set.
Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
6
A_BANK conversion could not be
performed.
Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy