8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-195
1345
SAFE CIRCUIT
SIGNAL NOT
SAME(SV)
Sub Code: XYY (Signifies the
power-ON unit No. and unmatched
signal No.)
X: Power-ON unit
0: Power-ON unit1 (TU#1)
1: Power-ON unit2 (TU#2)
2: Power-ON unit3 (TU#3)
3: Power-ON unit4 (TU#4)
4: Power-ON unit5 (TU#5)
5: Power-ON unit6 (TU#6)
YY: Unmatched signal
01: KMMA signal unmatched error
02: SVMAIN signal unmatched
error
03: SVMAIN1/2 signal unmatched
error
04: IORDY signal unmatched error
05: ONEN signal unmatched error
06: FUCUT signal unmatched
error
07: SHOCK1 signal unmatched
error
08: EXOT signal unmatched error
09: OT signal unmatched error
10: TUSONER signal unmatched
error
11: SVCMPER signal unmatched
error
12: TCER signal unmatched error
13: SON_OUT signal unmatched
error
14: BRRVER signal unmatched
error
60: Error due to unmatched output
signal for servo board failure
61: Error due to unmatched signal
for the main contactor state
(closed contact)
62: Error due to unmatched signal
for the main contactor state (open
contact)
63: Error due to unmatched input
signal for the main contractor
control relay
64: Error due to unmatched input
signal for the OT recovery
Connection failure
Check if the unmatched two double-checked signals are in agreement.
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy