8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-504
4
The Endless axis exceeded the
maximum pulse value (+-
536870911).
Setting error
(1)Check the following settings.
·Set the rotation amount so that the Endless axis does not exceed the
maximum pulse value.
4491
CORRECTIONAL
DIRECTION
ERROR
1
Control-group designation error for
correcting-direction preparation
Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
2
Designation error for the
correcting-direction coordinates
Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
3
When "any direction" is set for the
correcting direction, the correction
coordinates is not prepared.
Setting error
(1)Check the following settings.
·Check the settings for the correcting direction with the reference point
(REFP).
4
When "any direction" is set for the
correcting direction, the reference
points (REFP) are taught on the
same point.
Setting error
(1)Check the following settings.
·Check the settings for the reference points (REFP) so that each point is
different.
5
Designation error for the
coordinated motion control axis at
the reference point
Setting error
(1)Check the following settings.
·Match the control group designation of the wall point and weaving execution.
4492
POSITION
CORRECTION
ERROR
1
Data unmatched between the
correction amount data and the job
data:
The information about the control
groups designated for the series of
jobs, which is added to the
correction amount data, does not
include the valid control-group for
the job.
Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy