8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-560
4658
OVER SPEED
LIMIT
1
The taught speed was going to
exceed the limit during the multi
arm simultaneous operation.
Setting error
(1)Check the following settings.
·Reduce the teaching speed of the step where the alarm occurred to the
speed limit or less.
4657
WVADJ ERROR
1
The correction amplitude value did
not fall in the limit range.
Setting error
(1)Check the following settings.
·Correct the settings for "groove width correction limit value" specified for
S2C1259 and 1260.
4660
TIP DRESS
WATCH CANCEL
ERROR
Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
4661
MEMORY
ERROR(PRESS
COND FILE)
Sub Code: File number
Data error
(1)Reset the alarm.
(2)If the alarm occurs again, initialize the press characteristic file in
maintenance mode, and then load the press characteristic file saved in the
external memory device.
YCP01 board failure (1)Reset the alarm.
(2)If the alarm occurs again, replace the YCP01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YCP01 board, and then
insert the CF card which inserted original YCP01 board into the new YCP01
board.
YIF board failure
(1)Reset the alarm.
(2)If the alarm occurs again, replace the YIF board. Save the CMOS.BIN
before replace the board to be safe. Replace the YIF board, and then load
the CMOS.BIN saved before alarm occurred.
4662
PRESS SYNC
ERROR
4663
PRESS SYNC
MOTION ERROR
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy