8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-561
4666
UNDEFINED
WELD LENGTH
CHECK FILE
4670
INSUFFICIENT
NUM OF SAMPLE
DATA
Sub Code: Signifies the axis in
which the alarm occurred
Setting error
Lengthen the measurement section.
4671
SAMPLE BUFFER
OVER FLOW
Sub Code: Signifies the axis in
which the alarm occurred
Setting error
Shorten the measurement section.
4672
BASIC SPEED
UNREACHED
Sub Code: Signifies the axis in
which the alarm occurred
Setting error
Increase the speed specification value of a measurement job or set a small
value for BASICV.
Or set a small value for BASICT, or lengthen the measurement section.
4673
MAX TRQ
UNDETECTED
Sub Code: Signifies the axis in
which the alarm occurred
Setting error
Set a large value for the BASICT, and then check again.
4676
BROKEN FAN
FUSE
Connection failure
(1)Reset the alarm.
(2)If the alarm occurs again, check if there is a ground fault or short circuit in
the fan power line.
Fuse failure
(After cancellation of the short-circuit and ground fault) Replace the fuse.
4675
ERRSVCPU
SIGNAL ERROR
Connection failure
(1)Reset the alarm.
(2)If the alarm occurs again, check the connection and inserting state of the
following cables and connectors.
·CN210 YSU unit
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy