8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-259
4014
MEMORY
ERROR(ROBOT
CALIB FILE)
Sub Code: Page number
Data error
(1)Reset the alarm.
(2)If the alarm occurs again, initialize the file for calibration between
manipulators in maintenance mode, and then load the file for calibration
between manipulators saved in the external memory device.
YCP01 board failure (1)Reset the alarm.
(2)If the alarm occurs again, replace the YCP01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YCP01 board, and then
insert the CF card which inserted original YCP01 board into the new YCP01
board.
YIF board failure
(1)Reset the alarm.
(2)If the alarm occurs again, replace the YIF board. Save the CMOS.BIN
before replace the board to be safe. Replace the YIF board, and then load
the CMOS.BIN saved before alarm occurred.
4017
MEMORY
ERROR(POWER
SRC USER-DEF)
Data error
(1)Reset the alarm.
(2)If the alarm occurs again, initialize the Power Source user definition file in
maintenance mode, and then load the Power Source user definition file
saved in the external memory device.
YCP01 board failure (1)Reset the alarm.
(2)If the alarm occurs again, replace the YCP01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YCP01 board, and then
insert the CF card which inserted original YCP01 board into the new YCP01
board.
YIF board failure
(1)Reset the alarm.
(2)If the alarm occurs again, replace the YIF board. Save the CMOS.BIN
before replace the board to be safe. Replace the YIF board, and then load
the CMOS.BIN saved before alarm occurred.
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy