8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-201
Install failure
Check that the air inlet or outlet is not blocked.
1513
POWER SUPPLY
OVERHEAT(SERV
O)
The temperature
rises in the controller
Turn the power OFF then back ON after cooling the controller.
Connection failure
Check the power supply cable of the cooling fan in the CPS power unit.
CPS module failure
Replace the CPS power unit.
1514
OVERHEAT(AMPLI
FIER)
The temperature of
amplifier rose.
Turn the power OFF then back ON after cooling the amplifier.
1515
SON_OUT RELAY
STICKING(SERVO
I/O)
Circuit board
failure(YPU unit)
(1)Reset the alarm.
(2)If the alarm occurs again, replace the YPU unit. Save the CMOS.BIN
before replace the board to be safe.
1516
BRRCER RELAY
STICKING(SERVO
I/O)
Circuit board
failure(YPU unit)
(1)Reset the alarm.
(2)If the alarm occurs again, replace the YPU unit. Save the CMOS.BIN
before replace the board to be safe.
1530
ABSOLUTE DATA
ERROR(SERVO2)
Circuit board
failure(YPU unit)
(1)Reset the alarm.
(2)If the alarm occurs again, replace the YPU unit. Save the CMOS.BIN
before replace the board to be safe.
Module
failure(motor)
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, replace the motor.
Module
failure(SERVOPACK
)
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, replace the SERVOPACK.
1531
GATE ARRAY 1
ERROR(SERVO2)
Module
failure(SERVOPACK
)
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, replace the SERVOPACK
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy