8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-494
3277
4
The value for the signed 4-byte
data type variable exceeded the
maximum value.
Setting error
(1)Check the following settings.
·Check the settings for variable, and then correct the job to fall within the
input range of the tag.
3277
5
The value for the unsigned 4-byte
data type variable exceeded the
maximum value.
Setting error
(1)Check the following settings.
·Check the settings for variable, and then correct the job to fall within the
input range of the tag.
3277
6
The value for the real-number 4-
byte data type variable exceeded
the maximum value.
Setting error
(1)Check the following settings.
·Check the settings for variable, and then correct the job to fall within the
input range of the tag.
3278
2
The value for the character-string
type variable exceeded the
maximum value.
Setting error
(1)Check the following settings.
·Check the settings for variable, and then correct the job to fall within the
input range of the tag.
4447
DEFECTIVE
TAUGHT
POINT(CIRC)
Setting error
(1)Check the following settings.
·Check the settings for three teaching points so that circular interpolation
steps do not lie in a straight line.
4448
WEAVING
CONTROL ERROR
1
Weaving control-group designation
error
Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
4
When the speed is specified by
weaving time in the weaving file,
zero or the negative value is set for
the weaving time.
Setting error
(1)Check the following settings.
·Reset the value 0.1 seconds or more.
5
When the speed is specified by
frequency in the weaving file, zero
or the negative value is set for the
frequency.
Setting error
(1)Check the following settings.
·Reset the value 0.1 Hz or more.
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy
Содержание MOTOMAN DX100