8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-216
1594
MONITOR PLD
ERROR 3(SERVO
I/O)
Circuit board
failure(YPU unit)
(1)Reset the alarm.
(2)If the alarm occurs again, replace the YPU unit. Save the CMOS.BIN
before replace the board to be safe.
1650
FILE TRANSFER
DATA ERROR (SV)
1
An error occurred when the last
data was not received during the
first data communication at
execution of motion command.
Software operation
error occurred
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
EAXA board failure
(1)Turn the power OFF then back ON.
(2)If the error occurs again, save the CMOS.BIN in maintenance mode,
replace the following board.
· EAXA board
YCP01 board failure (1)Turn the power OFF then back ON.
If the error occurs again, save the CMOS.BIN in maintenance mode, and
then replace the YCP01 board. In this case, use the original CF card of the
YCP01 board.
YIF board failure
(1)Turn the power OFF then back ON.
(2)If the error occurs again, save the CMOS.BIN in maintenance mode,
replace the YIF board. and then load the CMOS.BIN previously saved in
maintenance mode.
2
An error occurred when the first
data was not received during on
the way data communication at
execution of motion command.
EAXA board failure
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, replace the EAXA board. Save the CMOS.BIN
before replace the board to be safe.
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy