8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-537
5
The setting for overlap is incorrect.
(1) For a rectangle, it is incorrectly
set as overlap > width/2.
(2) For a circle, it is incorrectly set
as overlap > ABS (2
π
* radius).
(3) For an ellipse, it is incorrectly
set as overlap >
π
* ABS
(width/2).
Setting error
(1)Check the following settings.
·Setting of the overlap data
6
The setting for the cutting speed is
incorrect. It is set as the cutting
speed > maximum linear speed.
Setting error
(1)Check the following settings.
·Setting of the cutting speed
7
Coordinated motion cannot be
used with the Form Cutting motion.
Setting error
(1)Check the following settings.
·Do not use the coordinated motion.
8
Zero or a negative value is set in
the minimum diameter parameter
(S1CxG063) for the Form Cutting
motion.
Setting error
(1)Check the following settings.
·The setting of the minimum diameter parameter (S1CxG063) for the Form
Cutting motion.
9
Zero or a negative value is set in
the maximum diameter parameter
(S1CxG064) for the Form Cutting
motion.
Setting error
(1)Check the following settings.
·The setting of the maximum diameter parameter (S1CxG063) for the Form
Cutting motion.
10
Although "PLACEMENT" or
"AUTO" is set for the start point
designation on the FORM CUT
SETTING window, the FORMAPR
instruction was not executed.
Setting error
(1)Check the following settings.
·Execute the FORMAPR instruction.
11
The Cut file setting of the
FORMAPR instruction is different
from that of the FORMCUT
instruction.
Setting error
(1)Check the following settings.
·The Cut file settings of FORMAPR and FORMCUT instructions must be
same.
12
A FORMAPR instruction was used
for the conventional FORMCUT
instruction.
Setting error
(1)Check the following settings.
·The FORMAPR instruction cannot be used for the conventional FORMCUT
instruction.
·Validate the new FORMCUT instruction.
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy
Содержание MOTOMAN DX100