8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-73
YIF board failure
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YIF01 board, and then load
the CMOS.BIN saved before alarm occurred.
19
The I/O module connected to the
4th PCI bus is different from the
function of the set I/O module.
Setting error
(1)Check the following settings.
· PCI slot number in which each PCI board is mounted
· I/O module settings in maintenance mode
Connection failure
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, check the connection and insertion of the
following connector.
· The PCI connector of the corresponding I/O module
Board failure(I/O
module)
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the following board. Save the
CMOS.BIN before replace the board to be safe.
· The corresponding I/O module (PCI board)
YIF board failure
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YIF01 board, and then load
the CMOS.BIN saved before alarm occurred.
0330
VERIFY
ERROR(APPLICAT
ION)
YCP01 board failure (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the YCP01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YCP01 board, and then
remove the CF from the failure YCP01 board to insert it into the new YCP01
board.
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy