8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-532
4569
UNDEFINED
PRESS
RESOLUTION
DATA
Sub Code: Press characteristic file
number
Setting error
(1)Check the following settings.
·Set the press resolution data to be used in the job.
4571
SERVO FLOAT
MODE RELEASE
ERR
Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
4572
NO SERVO GUN
CONTROL
GROUP
Setting error
(1)Check the following settings.
·Set the "motor gun axis" in the control group setting of maintenance mode.
4573
SPOT WELDER
NO. ERROR
Sub Code: Welder number
Setting error
(1)Check the following settings.
·Correct the welder number set in the gun characteristic file.
4574
SPOT WELD
COMPLETE TIME
LIMIT
Sub Code: Welder number
Setting error
(1)Check the following settings.
·Turn ON the timer contactor power.
·If the response from the timer takes too long time due to the system layout,
increase the timeout time.
4575
ERROR IN WELD
START TIMING
SET
Setting error
(1)Check the following settings.
·Check the settings for the "WST" tag.
·Check the settings for the pressure file.
4576
ERR IN MOTOR
GUN CONT MODE
Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
4577
ERR IN MOTOR
GUN MODE
RELEASE
Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).