8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-546
17
Memoplay debug error MOVL,
MOVC (continue)
Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
18
Memoplay debug error Same
point, moving amount is zero
(continue)
Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
19
Memoplay debug error Dividing
number error
Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
4611
OVER OPTON
INST EXECUTION
LIMIT
Setting error
(1)Check the following settings.
·Check the settings for the OPTON instruction. OPTON instruction can use
only the function to five simultaneously.
4612
TSYNC ERROR
Sub code: the number of
synchronizations of the first
executed TSYNC
Setting error
(1)Check the following settings.
·Check the settings for the number of synchronizations of the TSYNC
instruction.
4613
SERVO SEALER
GUN CONTROL
ERROR
1
The function designation
parameter is not set.
Setting error
(1)Check the following settings.
·Check the settings for the function designation parameter.
2
No sealer gun axis exists at the job
for which the sealer gun control
was attempted to be executed.
Setting error
(1)Check the following settings.
·Check the settings for the control-group of the job.
3
No robot axis exists at the job at
which an attempt was made to
execute sealer gun control.
Setting error
(1)Check the following settings.
·Check the settings for the control-group of the job.
4
Incorrect designation of the control
method for sealer gun control
Setting error
(1)Check the following settings.
·Set either "1" or "2" for PRM1 control method designation of the OPTON
instruction.