
8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-325
YIF board failure
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YIF01 board, and then load
the CMOS.BIN saved before alarm occurred.
YCP01 board failure (1)Reset the alarm, and then try again.
(2)If the alarm occurs again, replace the YCP01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YCP01 board, and then
insert the CF card which inserted original YCP01 board into the new YCP01
board.
-18
The number of instructions added
to a job exceeded 9999.
Setting error
(1)Check the following settings.
·Delete unnecessary instructions and add new instructions again.
-19
The number of steps added to a
job exceeded 999.
Setting error
(1)Check the following settings.
Delete unnecessary steps and add new steps again.
-22
Job information was not able to be
expanded.
Software operation
error occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
YIF board failure
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YIF01 board, and then load
the CMOS.BIN saved before alarm occurred.
YCP01 board failure (1)Reset the alarm, and then try again.
(2)If the alarm occurs again, replace the YCP01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YCP01 board, and then
insert the CF card which inserted original YCP01 board into the new YCP01
board.
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy
Содержание MOTOMAN DX100
Страница 728: ...DX100 Index Index v X XYZ coordinate data 8 3 ...