73
Incorrect setting of the DHCP
parameter which is used in the
Ethernet function of the DNS.
Setting error
(1)Check the following settings.
· · DNS setting of network in maintenance mode
74
Incorrect setting of the DHCP
parameter which is used in the
Ethernet function of the DNS.
Setting error
(1)Check the following settings.
· DNS setting of network in maintenance mode
75
Incorrect setting of the domain
which is used in the Ethernet
function.
Setting error
(1)Check the following settings.
· Domain name of network in maintenance mode
1221
ETHERNET
INITIAL PROCESS
ERROR
1
An error occurred in the device
initialization process of the
Ethernet function.
Software operation
error occurred
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
YCP01 board failure (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the YCP01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YCP01 board, and then
remove the CF from the failure YCP01 board to insert it into the new YCP01
board.
2
An error occurred in the IP address
setting process of the Ethernet
function.
Software operation
error occurred
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance mode, and
then contact your Yaskawa representative about occurrence status
(operating procedure).
YCP01 board failure (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the YCP01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YCP01 board, and then
remove the CF from the failure YCP01 board to insert it into the new YCP01
board.