8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-24
3
An error was detected in
communications with the I/O
module board connected with 3rd
serial bus when the control power
turned ON.
Setting error
(1)Check the following settings.
· The rotary switch setting which specifies slot numbers of each I/O module
· I/O module settings in maintenance mode
Connection failure
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, check the connection and insertion of the
following cables and connectors.
· The MII communications cable which I/O module of the corresponding node
number
· (In case of MII communications last station) Terminator
· 24V power of the corresponding I/O module
Board failure(I/O
module)
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the following board. Save the
CMOS.BIN before replace the board to be safe.
YIF board failure
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YIF01 board, and then load
the CMOS.BIN saved before alarm occurred.
4
An error was detected in
communications with the I/O
module board connected with 4th
serial bus when the control power
turned ON.
Setting error
(1)Check the following settings.
· The rotary switch setting which specifies slot numbers of each I/O module
· I/O module settings in maintenance mode
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy
Содержание MOTOMAN DX100