8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-186
1328
DEFECTIVE
ENCODER
Sub Code: Signifies the axis in
which the alarm occurred
Connection failure
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, check the connection and insertion of the
following cables and connectors.
[Robot axis]
· Cable between encoders
· EAXA-CN508
[External axis]
· Cable between encoders
· EAXB-CN0534,535,536
Module
failure(encoder)
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, replace the encoder.
EAXA board failure
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, replace the EAXA board. Save the CMOS.BIN
before replace the board to be safe.
1329
DEFECTIVE
SERIAL
ENCODER
COMMAND
Sub Code: Signifies the axis in
which the alarm occurred
Connection failure
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, check the connection and insertion of the
following cables and connectors.
[Robot axis]
· Cable between encoders
· EAXA-CN508
[External axis]
· Cable between encoders
· EAXB-CN0534,535,536
Module
failure(encoder)
(1)Reset the alarm.(In case of major alarm, turn the power OFF then back
ON.)
(2)If the alarm occurs again, replace the encoder.
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy