8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-258
4012
MEMORY
ERROR(LINK
SERVOFLOAT)
Sub Code: Condition file number
Data error
(1)Reset the alarm.
(2)If the alarm occurs again, initialize the link servo float condition file in
maintenance mode, and then load the link servo float condition file saved in
the external memory device.
YCP01 board failure (1)Reset the alarm.
(2)If the alarm occurs again, replace the YCP01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YCP01 board, and then
insert the CF card which inserted original YCP01 board into the new YCP01
board.
YIF board failure
(1)Reset the alarm.
(2)If the alarm occurs again, replace the YIF board. Save the CMOS.BIN
before replace the board to be safe. Replace the YIF board, and then load
the CMOS.BIN saved before alarm occurred.
4013
MEMORY
ERROR(LINEAR
SERVOFLOAT)
Sub Code: Condition file number
Data error
(1)Reset the alarm.
(2)If the alarm occurs again, initialize the linear servo float condition file in
maintenance mode, and then load the linear servo float condition file saved
in the external memory device.
YCP01 board failure (1)Reset the alarm.
(2)If the alarm occurs again, replace the YCP01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YCP01 board, and then
insert the CF card which inserted original YCP01 board into the new YCP01
board.
YIF board failure
(1)Reset the alarm.
(2)If the alarm occurs again, replace the YIF board. Save the CMOS.BIN
before replace the board to be safe. Replace the YIF board, and then load
the CMOS.BIN saved before alarm occurred.
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy