8A
la
rm
DX100
8.3
A
la
rm Me
ssa
ge List
8-93
0609
MEDAR
PARAMETER
ERROR
MADER timer error
Refer to the instruction manual for the MEDAR function.
0610
MEDAR STEPPER
TRANSMIT
ERROR
MADER timer error
Refer to the instruction manual for the MEDAR function.
0710
LADDER
INITIALIZE
ERROR
Data error
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, initialize the appropriate data in maintenance
mode, and then load the data saved in the external memory device.
YCP01 board failure (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the YCP01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YCP01 board, and then
remove the CF from the failure YCP01 board to insert it into the new YCP01
board.
YIF board failure
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the YIF01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YIF01 board, and then load
the CMOS.BIN saved before alarm occurred.
0720
LADDER
PROGRAM
ERROR
1
An error was found in the relay No.
specification.
Data error
(1)Turn the power OFF then back ON.
(2)If the alarm occurs again, initialize the appropriate data in maintenance
mode, and then load the data saved in the external memory device.
YCP01 board failure (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the YCP01 board. Save the CMOS.BIN
before replace the board to be safe. Replace the YCP01 board, and then
remove the CF from the failure YCP01 board to insert it into the new YCP01
board.
Alarm
Number
Alarm Name
Sub
Code
Meaning
Cause
Remedy