5.5.4 Monitoring device connections
The units KS 220 and KS…Ex are equipped with a ther-
mal motor monitor and a humidity sensor for the
motor.
Temperature monitoring is achieved with a single tem-
perature circuit consisting of bimetal temperature sen-
sors.
When used in areas with an explosion hazard, the
temperature monitoring device must be con-
nected in such a way that if it is triggered it can
only be restarted once the “release button” has
been manually activated!
On versions with switching devices, the monitoring
devices are connected and set accordingly.
The monitoring devices must be connected separately
on units with free cable ends!
Appropriate evaluation relays and settings are recom-
mended for this:
• Temperature monitoring:
• Relay: CM-MSS
• Threshold: Preset
• Triggered condition: Shutdown
• Humidity sensor:
• Relay: NIV 101
• Threshold: 30 kOhm
• Triggered condition: Warning or shutdown
All relays must be installed and connected out-
side the area with the explosion hazard!
Optional monitoring devices
• Leak electrode to monitor the sealing chamber for
leakages:
• Sensor: Leak electrode
• Relay: ER 143
• Threshold: 30 kOhm
• Triggered condition: Warning or shutdown
For this reason, no warranty claims can be accepted for
damages resulting from unsuitable monitoring!
5.6 Motor protection and activation types
5.6.1 Motor protection
The minimum requirement is a thermal relay/motor
protection switch with temperature compensation,
differential triggering and an anti-reactivation device in
accordance with VDE 0660 or the appropriate national
regulations.
If the product is connected to electrical systems in
which faults frequently occur, we recommend install-
ing additional protective devices at the customer
(overvoltage, undervoltage or phase failure relays,
lightning protection etc.). We also recommend install-
ing an earth leakage circuit breaker.
Local and national regulations must be adhered to
when connecting the product.
5.6.2 Activation types
Direct activation
At full load, the motor protection should be set to the
rated current at the operating point (see type plate). At
partial load, we recommend that the motor protection
be set 5% above the current measured at the operat-
ing point.
Starting transformer/soft start
Motor protection should be set to the rated current
when fully loaded. At partial load, we recommend that
the motor protection be set 5 % above the current
measured at the operating point. Start up time with
reduced voltage (approx. 70 %) is a maximum of
3 seconds.
Operation with frequency transformers
The product may not be operated on frequency trans-
formers.
Products with plugs/switching devices
Insert the plug into the plug socket and press the on/
off switch or let the product switch on/off automati-
cally by means of the attached level control system.
Switching devices can be ordered as accessories for
products with free cable ends. In this case, also observe
the instructions enclosed with the switching device.
Plugs and switching devices are not flood-proof.
Note the IP protection class. Always install
switching devices in such a way that they are
protected from flooding.
6 Startup
The “Start-up” chapter contains all the important
instructions for the operating personnel for starting up
and operating the product safely.
The following constraints must be adhered to and
monitored:
• Type of installation
• Operating mode
• Minimum water coverage / max. submersion
If the machine has not been operated for an
extended period, these constraints must also be
checked and any discovered faults rectified.
This manual must always be kept either by the product
or in a place specially reserved for it, where it is accessi-
ble for the entire operating personnel at all times.
KS…Ex (7-wire connection cable)
Wire no.
Terminal
1
PTC
2
PTC
3
U
4
V
5
W
6
DK
Green/yellow
PE
Содержание EMU KS Ex Series
Страница 4: ......
Страница 6: ......
Страница 46: ......
Страница 127: ...Wilo EMU KS KS Ex 127 1 1 1 1 2 2 1 3 18 1 4 1 4 1 1 4 2 1 5 1 6 1 7...
Страница 128: ...128 WILO SE 05 2011 V4 1WE 1 7 1 1 7 2 12 18 1 7 3 1 7 4 1 7 5 1 7 6 2 2 1 2 1 1 2 1 2...
Страница 129: ...Wilo EMU KS KS Ex 129 DIN ANSI 2 2 2 3...
Страница 130: ...130 WILO SE 05 2011 V4 1WE VDE 2 4 CE CE 2 5 VDE 0100 2 6 RCD 2 7 IP 68 2 8 PT100...
Страница 131: ...Wilo EMU KS KS Ex 131 2 9 2 10 Ex Ex Ex Ex 2 11 2 12 kW 70 dB A 110 dB A...
Страница 132: ...132 WILO SE 05 2011 V4 1WE 3 3 1 3 2 3 3 1 15 C 5 C 25 C 3 C 4 85 dB A...
Страница 137: ...Wilo EMU KS KS Ex 137 5 2 5 3 5 4 5 4 1 2 1 1 4 2 5 3 6...
Страница 138: ...138 WILO SE 05 2011 V4 1WE 2 3 4 5 6 7 5 4 2 3 1 Storz 2 3 4 5 6 5 4 3 4 S 1 Storz 4 2 Storz 5 3 6 40 C 1 3 On 2 Off 4...
Страница 140: ...140 WILO SE 05 2011 V4 1WE CM MSS NIV 101 30 k ER 143 30 k 5 6 5 6 1 VDE 0660 5 6 2 5 5 70 3 IP 6...
Страница 141: ...Wilo EMU KS KS Ex 141 6 1 VDE 6 2 6 2 1 6 2 2 Wilo Wilo 2 2 U1 V1 U2 V2 6 2 3 CEE 5 CEE CEE 180 6 3...
Страница 143: ...Wilo EMU KS KS Ex 143 AUTO 0 OFF 6 5 3 6 6 5 2 5 1 7 7 1 3 C...
Страница 147: ...Wilo EMU KS KS Ex 147 9 9 0 1 1 2 3 9 0 2 1 2 3 2 4 3 5 2 6 7 9 0 3 1 2 3 4 5 9 0 4 1 2 3 4 2 5 6 7...
Страница 148: ...148 WILO SE 05 2011 V4 1WE 8 9 10 2 11 9 0 5 1 2 3 4 5 2 6 2 7 8 9 9 0 6 1 5 2 10 m 3 4 5 9 0 7 10...
Страница 222: ......
Страница 244: ......
Страница 264: ......
Страница 265: ...Wilo EMU KS KS Ex 265 1 1 1 1 2 2 1 3 1 4 1 4 1 1 5 1 6 1 7...
Страница 266: ...266 WILO SE 05 2011 V4 1WE 1 7 1 1 7 2 12 18 1 7 3 1 7 4 1 7 5 1 7 6 2 2 1 2 1 1...
Страница 267: ...Wilo EMU KS KS Ex 267 2 1 2 DIN ANSI 2 2...
Страница 268: ...268 WILO SE 05 2011 V4 1WE 2 3 VDE 2 4 CE 2 5 VDE 0100 2 6 2 7 IP 68 2 8 PT100...
Страница 269: ...Wilo EMU KS KS Ex 269 2 9 2 10 Ex 2 11...
Страница 270: ...270 WILO SE 05 2011 V4 1WE 2 12 70 A 110 A 3 3 1 3 2 3 3 1 15 C 5 C 25 C 3 4 85 A...
Страница 271: ...Wilo EMU KS KS Ex 271 6 3 4 4 4 1 Wilo EMU KS 6 KS 12 KS 20 45 Wilo EMU KS KTW 4 2 Wilo EMU KS DIN VDE 0100 702 46...
Страница 275: ...Wilo EMU KS KS Ex 275 5 1 5 2 5 3 5 4...
Страница 276: ...276 WILO SE 05 2011 V4 1WE 5 4 1 2 1 2 3 4 5 6 7 5 4 2 3 1 Storz 2 3 4 5 6 1 4 2 5 3 6 1 Storz 4 O 2 Storz 5 3 6 40 C...
Страница 279: ...Wilo EMU KS KS Ex 279 5 6 2 5 5 70 3 IP 6 6 1 VDE 6 2...
Страница 281: ...Wilo EMU KS KS Ex 281 CEE IP CEE 6 5 1 6 5 2 I ON 0 OFF AUTO 0 OFF 6 5 3 6 6 5 2...
Страница 282: ...282 WILO SE 05 2011 V4 1WE 5 1 7 7 1 3 C 5 7 2 7 2 1 7 2 2 7 3 40 C...
Страница 287: ...Wilo EMU KS KS Ex 287 9 9 0 6 1 5 2 10 3 4 5 9 0 7 10...
Страница 288: ......
Страница 308: ......
Страница 328: ......
Страница 329: ...Wilo EMU KS KS Ex 329 1 1 1 1 2 2 1 3 1 4 1 4 1 1 4 2 1 5 1 6 1 7 1 7 1 a...
Страница 330: ...330 WILO SE 05 2011 V4 1WE 1 7 2 12 18 1 7 3 1 7 4 1 7 5 1 7 6 2 2 1 2 1 1 2 1 2...
Страница 331: ...Wilo EMU KS KS Ex 331 DIN ANSI 2 2 2 3 VDE 2 4 CE...
Страница 332: ...332 WILO SE 05 2011 V4 1WE 2 5 VDE 0100 2 6 E RCD 2 7 IP 68 2 8 100 2 9...
Страница 333: ...Wilo EMU KS KS Ex 333 2 10 Ex Ex 2 11 2 12 kW 70 dB A 110 dB A 3 3 1 3 2 85 dB A...
Страница 334: ...334 WILO SE 05 2011 V4 1WE 3 3 1 15 C 5 C 25 C 3 C 4 6 3 4 4...
Страница 338: ...338 WILO SE 05 2011 V4 1WE 4 10 50 m 10 m Ceram 5 5 1 ATV 5 2 5 3 5 4...
Страница 339: ...Wilo EMU KS KS Ex 339 5 4 1 2 1 2 3 4 5 6 7 5 4 2 3 1 2 3 4 5 1 4 2 5 3 6 1 4 2 5 3 6...
Страница 342: ...342 WILO SE 05 2011 V4 1WE 5 5 70 3 IP 6 6 1 VDE 6 2 6 2 1...
Страница 344: ...344 WILO SE 05 2011 V4 1WE 6 5 2 I ON 0 OFF AUTO 0 OFF 6 5 3 6 6 5 2 5 1 7 7 1...
Страница 348: ...348 WILO SE 05 2011 V4 1WE 9 9 0 1 1 2 3 9 0 2 1 2 3 4 5 6 7 9 0 3 1 2 3 4 5 9 0 4 1 2 3 4 5 6 7 8 9 10...
Страница 349: ...Wilo EMU KS KS Ex 349 11 9 0 5 1 2 3 4 5 6 7 8 9 9 0 6 1 5 2 10 m 3 4 5 9 0 7 10...
Страница 350: ......
Страница 371: ...I Wilo EMU KS KS Ex 371 1 1 1 1 2 2 1 3 1 4 1 4 1 1 4 2 1 5 1 6 1 7...
Страница 372: ...372 WILO SE 05 2011 V4 1WE 1 7 1 1 7 2 12 18 1 7 3 1 7 4 1 7 5 1 7 6 2 2 1 2 1 1 2 1 2...
Страница 373: ...I Wilo EMU KS KS Ex 373 DIN ANSI 2 2 2 3...
Страница 374: ...374 WILO SE 05 2011 V4 1WE VDE 2 4 CE CE 2 5 VDE 0100 2 6 RCD 2 7 IP 68 2 8 PT100 2 9...
Страница 375: ...I Wilo EMU KS KS Ex 375 2 10 Ex 2 11 2 12 70 110 A 3 3 1 3 2 85 A...
Страница 376: ...376 WILO SE 05 2011 V4 1WE 3 3 1 15 C 5 C 25 C 3 C 4 6...
Страница 381: ...I Wilo EMU KS KS Ex 381 5 4 5 4 1 2 1 2 3 4 5 6 7 5 4 2 3 1 4 2 5 3 6 1 Storz 4 2 Storz 5 3 6...
Страница 382: ...382 WILO SE 05 2011 V4 1WE 1 Storz 2 3 4 5 6 5 4 3 4 S 5 5 RCD 5 5 1 40 C 1 3 2 4...
Страница 384: ...384 WILO SE 05 2011 V4 1WE 5 6 2 5 5 70 3 IP 6 6 1 VDE 6 2...
Страница 386: ...386 WILO SE 05 2011 V4 1WE CEE IP CEE 6 5 1 6 5 2 ON 0 OFF AUTO 0 OFF 6 5 3 6 6 5 2 5 1 7...
Страница 387: ...I Wilo EMU KS KS Ex 387 7 1 3 C 5 7 2 7 2 1 7 2 2 7 3 7 4 7 4 1 75 439 EWG 5a 5b AbfG 1 VwVwS 1999 DIN 52 900 40 C...
Страница 388: ...388 WILO SE 05 2011 V4 1WE 7 4 2 TA 524 02 91 689 EWG 7 4 3 8 Wilo 1 2 DIN EN 60079 1 A4 70 75 439 EWG 5a 5b AbfG...
Страница 390: ...390 WILO SE 05 2011 V4 1WE 8 3 3 8 4 8000 2 Wilo 8 5 9 9 0 1 1 2 3 9 0 2 1 2 3 2 4 3 5 2 6 7 9 0 3 1 2 3 4 5...
Страница 391: ...I Wilo EMU KS KS Ex 391 9 0 4 1 2 3 4 2 5 6 7 8 9 10 2 11 9 0 5 1 2 3 4 5 2 6 2 7 8 9 9 0 6 1 5 2 10 3 4 5 9 0 7 10...
Страница 392: ......
Страница 397: ......
Страница 398: ......