Installation and operating instructions Wilo-EMU KS.../KS...Ex
37
5.4.3 Level control
Fig. 4:
Level control with one float switch
Fill levels can be determined using the level control
system, meaning the unit is switched on and off auto-
matically. The fill level can be recorded using float
switches, pressure and ultrasound measurements or
electrodes.
Note the following information:
• When using float switches, ensure that they can move
freely in the operating area!
• The water level must not fall below the minimum!
• The maximum starts per hour may not be exceeded!
• If the fill levels fluctuate strongly, then a level control
should be made on two test points as standard. This
means larger differential gaps are reached.
Installation
The "S" version in this series is equipped with a float
switch for measuring the level. A contact is opened or
closed here, depending on the angle of inclination on
the float switch.
The switching level is defined by the cable length on
the float switch. Only smaller differential gaps can be
reached here.
• Fasten the cable of the float switch in the operating
area (e.g. on the pressure pipe or wall).
• Select the cable length so that the desired switching
level is reached.
Observe the information on the maximum starts
per hour and the minimum water level!
5.5 Electrical connection
• Mains current and voltage must correspond to the
details on the type plate.
• Connect the power supply cable in accordance with
the applicable standards and regulations and accord-
ing to the wire assignment.
• Any available monitoring equipment, e.g. for the motor
temperature, must be connected and tested to ensure
that it is working properly.
• For three-phase current motors, a clockwise rotating
field must be available.
• Ground the product properly.
Products that are permanently installed must be
grounded in compliance with nationally applicable
standards. If a separate grounding conductor is avail-
able, it must be connected to the marked hole or
grounding terminal (
;
) using a suitable screw, nut,
toothed washer and flat washer. The cross section of
the cable for the grounding conductor connection
must correspond to the local regulations.
•
A motor protection switch must be used.
We recom-
mend using an earth leakage circuit breaker (RCD)
• Switching devices are to be purchased as accessories.
5.5.1 Technical details
• Activation type: Direct
• Power supply fuse:
• KS 8 to KS 37: 10 A
• KS 70: 20 A
• KS 220: 63 A
• KS…Ex: 10 A
• Cable cross section
• KS 8 to KS 37: 4G1.5
• KS 70: 4G2.5
• KS 220: 4G6
• KS…Ex: 7G1.5
Only slow-blow fuses or K characteristic automatic
cut-outs may be used for pre-fusing.
5.5.2 AC motor
The AC version is delivered ready to plug in. To con-
nect it to the electricity supply, plug it into the power
socket.
Special versions with free cable ends are connected to
the electricity supply by connecting them to the
switch box.
Electrical connections may only be made by a
qualified electrician!
The wires of the connection cable are assigned as fol-
lows:
5.5.3 Three-phase current motor
The three-phase version can be delivered with a CEE
plug or free cable ends:
• The version with a CEE plug is connected to the elec-
tricity supply by plugging it into the electricity socket.
• The version with free cable ends is connected to the
electricity supply by connecting to the switch box.
Electrical connections may only be made by a
qualified electrician!
The wires of the connection cable are assigned as fol-
lows:
1
Unit
3
"On" switch position
2
Minimum water level
"Off" switch position
4
Differential gap
Risk of fatal injury due to electrical current!
There is a risk of fatal electric shocks caused by
improper electrical connections. Electrical con-
nections may only be carried out by a qualified
electrician who is approved by the local power
supplier, in accordance with locally applicable
regulations.
3-wire connection cable
Wire color
Terminal
Black
L
Blue
N
Green/yellow
PE
KS… (4-wire connection cable)
Wire color
Terminal
Brown
U
Black
V
Gray
W
Green/yellow
PE
Содержание EMU KS Ex Series
Страница 4: ......
Страница 6: ......
Страница 46: ......
Страница 127: ...Wilo EMU KS KS Ex 127 1 1 1 1 2 2 1 3 18 1 4 1 4 1 1 4 2 1 5 1 6 1 7...
Страница 128: ...128 WILO SE 05 2011 V4 1WE 1 7 1 1 7 2 12 18 1 7 3 1 7 4 1 7 5 1 7 6 2 2 1 2 1 1 2 1 2...
Страница 129: ...Wilo EMU KS KS Ex 129 DIN ANSI 2 2 2 3...
Страница 130: ...130 WILO SE 05 2011 V4 1WE VDE 2 4 CE CE 2 5 VDE 0100 2 6 RCD 2 7 IP 68 2 8 PT100...
Страница 131: ...Wilo EMU KS KS Ex 131 2 9 2 10 Ex Ex Ex Ex 2 11 2 12 kW 70 dB A 110 dB A...
Страница 132: ...132 WILO SE 05 2011 V4 1WE 3 3 1 3 2 3 3 1 15 C 5 C 25 C 3 C 4 85 dB A...
Страница 137: ...Wilo EMU KS KS Ex 137 5 2 5 3 5 4 5 4 1 2 1 1 4 2 5 3 6...
Страница 138: ...138 WILO SE 05 2011 V4 1WE 2 3 4 5 6 7 5 4 2 3 1 Storz 2 3 4 5 6 5 4 3 4 S 1 Storz 4 2 Storz 5 3 6 40 C 1 3 On 2 Off 4...
Страница 140: ...140 WILO SE 05 2011 V4 1WE CM MSS NIV 101 30 k ER 143 30 k 5 6 5 6 1 VDE 0660 5 6 2 5 5 70 3 IP 6...
Страница 141: ...Wilo EMU KS KS Ex 141 6 1 VDE 6 2 6 2 1 6 2 2 Wilo Wilo 2 2 U1 V1 U2 V2 6 2 3 CEE 5 CEE CEE 180 6 3...
Страница 143: ...Wilo EMU KS KS Ex 143 AUTO 0 OFF 6 5 3 6 6 5 2 5 1 7 7 1 3 C...
Страница 147: ...Wilo EMU KS KS Ex 147 9 9 0 1 1 2 3 9 0 2 1 2 3 2 4 3 5 2 6 7 9 0 3 1 2 3 4 5 9 0 4 1 2 3 4 2 5 6 7...
Страница 148: ...148 WILO SE 05 2011 V4 1WE 8 9 10 2 11 9 0 5 1 2 3 4 5 2 6 2 7 8 9 9 0 6 1 5 2 10 m 3 4 5 9 0 7 10...
Страница 222: ......
Страница 244: ......
Страница 264: ......
Страница 265: ...Wilo EMU KS KS Ex 265 1 1 1 1 2 2 1 3 1 4 1 4 1 1 5 1 6 1 7...
Страница 266: ...266 WILO SE 05 2011 V4 1WE 1 7 1 1 7 2 12 18 1 7 3 1 7 4 1 7 5 1 7 6 2 2 1 2 1 1...
Страница 267: ...Wilo EMU KS KS Ex 267 2 1 2 DIN ANSI 2 2...
Страница 268: ...268 WILO SE 05 2011 V4 1WE 2 3 VDE 2 4 CE 2 5 VDE 0100 2 6 2 7 IP 68 2 8 PT100...
Страница 269: ...Wilo EMU KS KS Ex 269 2 9 2 10 Ex 2 11...
Страница 270: ...270 WILO SE 05 2011 V4 1WE 2 12 70 A 110 A 3 3 1 3 2 3 3 1 15 C 5 C 25 C 3 4 85 A...
Страница 271: ...Wilo EMU KS KS Ex 271 6 3 4 4 4 1 Wilo EMU KS 6 KS 12 KS 20 45 Wilo EMU KS KTW 4 2 Wilo EMU KS DIN VDE 0100 702 46...
Страница 275: ...Wilo EMU KS KS Ex 275 5 1 5 2 5 3 5 4...
Страница 276: ...276 WILO SE 05 2011 V4 1WE 5 4 1 2 1 2 3 4 5 6 7 5 4 2 3 1 Storz 2 3 4 5 6 1 4 2 5 3 6 1 Storz 4 O 2 Storz 5 3 6 40 C...
Страница 279: ...Wilo EMU KS KS Ex 279 5 6 2 5 5 70 3 IP 6 6 1 VDE 6 2...
Страница 281: ...Wilo EMU KS KS Ex 281 CEE IP CEE 6 5 1 6 5 2 I ON 0 OFF AUTO 0 OFF 6 5 3 6 6 5 2...
Страница 282: ...282 WILO SE 05 2011 V4 1WE 5 1 7 7 1 3 C 5 7 2 7 2 1 7 2 2 7 3 40 C...
Страница 287: ...Wilo EMU KS KS Ex 287 9 9 0 6 1 5 2 10 3 4 5 9 0 7 10...
Страница 288: ......
Страница 308: ......
Страница 328: ......
Страница 329: ...Wilo EMU KS KS Ex 329 1 1 1 1 2 2 1 3 1 4 1 4 1 1 4 2 1 5 1 6 1 7 1 7 1 a...
Страница 330: ...330 WILO SE 05 2011 V4 1WE 1 7 2 12 18 1 7 3 1 7 4 1 7 5 1 7 6 2 2 1 2 1 1 2 1 2...
Страница 331: ...Wilo EMU KS KS Ex 331 DIN ANSI 2 2 2 3 VDE 2 4 CE...
Страница 332: ...332 WILO SE 05 2011 V4 1WE 2 5 VDE 0100 2 6 E RCD 2 7 IP 68 2 8 100 2 9...
Страница 333: ...Wilo EMU KS KS Ex 333 2 10 Ex Ex 2 11 2 12 kW 70 dB A 110 dB A 3 3 1 3 2 85 dB A...
Страница 334: ...334 WILO SE 05 2011 V4 1WE 3 3 1 15 C 5 C 25 C 3 C 4 6 3 4 4...
Страница 338: ...338 WILO SE 05 2011 V4 1WE 4 10 50 m 10 m Ceram 5 5 1 ATV 5 2 5 3 5 4...
Страница 339: ...Wilo EMU KS KS Ex 339 5 4 1 2 1 2 3 4 5 6 7 5 4 2 3 1 2 3 4 5 1 4 2 5 3 6 1 4 2 5 3 6...
Страница 342: ...342 WILO SE 05 2011 V4 1WE 5 5 70 3 IP 6 6 1 VDE 6 2 6 2 1...
Страница 344: ...344 WILO SE 05 2011 V4 1WE 6 5 2 I ON 0 OFF AUTO 0 OFF 6 5 3 6 6 5 2 5 1 7 7 1...
Страница 348: ...348 WILO SE 05 2011 V4 1WE 9 9 0 1 1 2 3 9 0 2 1 2 3 4 5 6 7 9 0 3 1 2 3 4 5 9 0 4 1 2 3 4 5 6 7 8 9 10...
Страница 349: ...Wilo EMU KS KS Ex 349 11 9 0 5 1 2 3 4 5 6 7 8 9 9 0 6 1 5 2 10 m 3 4 5 9 0 7 10...
Страница 350: ......
Страница 371: ...I Wilo EMU KS KS Ex 371 1 1 1 1 2 2 1 3 1 4 1 4 1 1 4 2 1 5 1 6 1 7...
Страница 372: ...372 WILO SE 05 2011 V4 1WE 1 7 1 1 7 2 12 18 1 7 3 1 7 4 1 7 5 1 7 6 2 2 1 2 1 1 2 1 2...
Страница 373: ...I Wilo EMU KS KS Ex 373 DIN ANSI 2 2 2 3...
Страница 374: ...374 WILO SE 05 2011 V4 1WE VDE 2 4 CE CE 2 5 VDE 0100 2 6 RCD 2 7 IP 68 2 8 PT100 2 9...
Страница 375: ...I Wilo EMU KS KS Ex 375 2 10 Ex 2 11 2 12 70 110 A 3 3 1 3 2 85 A...
Страница 376: ...376 WILO SE 05 2011 V4 1WE 3 3 1 15 C 5 C 25 C 3 C 4 6...
Страница 381: ...I Wilo EMU KS KS Ex 381 5 4 5 4 1 2 1 2 3 4 5 6 7 5 4 2 3 1 4 2 5 3 6 1 Storz 4 2 Storz 5 3 6...
Страница 382: ...382 WILO SE 05 2011 V4 1WE 1 Storz 2 3 4 5 6 5 4 3 4 S 5 5 RCD 5 5 1 40 C 1 3 2 4...
Страница 384: ...384 WILO SE 05 2011 V4 1WE 5 6 2 5 5 70 3 IP 6 6 1 VDE 6 2...
Страница 386: ...386 WILO SE 05 2011 V4 1WE CEE IP CEE 6 5 1 6 5 2 ON 0 OFF AUTO 0 OFF 6 5 3 6 6 5 2 5 1 7...
Страница 387: ...I Wilo EMU KS KS Ex 387 7 1 3 C 5 7 2 7 2 1 7 2 2 7 3 7 4 7 4 1 75 439 EWG 5a 5b AbfG 1 VwVwS 1999 DIN 52 900 40 C...
Страница 388: ...388 WILO SE 05 2011 V4 1WE 7 4 2 TA 524 02 91 689 EWG 7 4 3 8 Wilo 1 2 DIN EN 60079 1 A4 70 75 439 EWG 5a 5b AbfG...
Страница 390: ...390 WILO SE 05 2011 V4 1WE 8 3 3 8 4 8000 2 Wilo 8 5 9 9 0 1 1 2 3 9 0 2 1 2 3 2 4 3 5 2 6 7 9 0 3 1 2 3 4 5...
Страница 391: ...I Wilo EMU KS KS Ex 391 9 0 4 1 2 3 4 2 5 6 7 8 9 10 2 11 9 0 5 1 2 3 4 5 2 6 2 7 8 9 9 0 6 1 5 2 10 3 4 5 9 0 7 10...
Страница 392: ......
Страница 397: ......
Страница 398: ......