Remote Control Commands
R&S
®
SMBV100A
579
Operating Manual 1176.8016.02 ─ 17
Furthermore the following suffixes denote:
●
Sensor assignment
READ<ch>
and
INIate<hw>
; range: [1] to 4
●
Sensor mapping list:
ELEMent<ch>
; range [1] to 25
:SENSe<ch>[:POWer]:APERture:DEFault:STATe
............................................................. 579
:SENSe<ch>[:POWer]:APERture:TIMe
.............................................................................579
:INITiate<ch>[:POWer]:CONTinuous
................................................................................580
:SENSe<ch>[:POWer]:CORRection:SPDevice:SELect
.......................................................581
:SENSe<ch>[:POWer]:CORRection:SPDevice:STATe
....................................................... 581
:SENSe<ch>[:POWer]:CORRection:SPDevice:LIST?
........................................................ 581
:SENSe<ch>[:POWer]:DISPlay:PERManent:STATe
.......................................................... 582
:SENSe<ch>[:POWer]:DISPlay:PERManent:PRIority
.........................................................582
:SENSe<ch>[:POWer]:FILTer:LENGth:AUTO?
..................................................................582
:SENSe<ch>[:POWer]:FILTer:LENGth[:USER]
..................................................................583
:SENSe<ch>[:POWer]:FILTer:NSRatio
.............................................................................583
:SENSe<ch>[:POWer]:FILTer:NSRatio:MTIMe
..................................................................583
:SENSe<ch>[:POWer]:FILTer:SONCe
..............................................................................584
:SENSe<ch>[:POWer]:FILTer:TYPE
................................................................................ 584
:SENSe<ch>[:POWer]:LOGGing:STATe
...........................................................................585
..................................................................................585
........................................................................................ 586
:SENSe<ch>[:POWer]:OFFSet:STATe
............................................................................. 586
.................................................................................... 586
.......................................................................................587
SENSe<ch>[:POWer]:STATus[:DEVice]?
......................................................................... 587
....................................................................................587
..........................................................................................588
.......................................................................................... 588
............................................................................................588
:SENSe<ch>[:POWer]:APERture:DEFault:STATe
<UseDefAp>
Deactivates the default aperture time of the respective sensor.
To specify a user-defined value, use the command
Parameters:
<UseDefAp>
0 | 1 | OFF | ON
*RST:
1
Example:
SENS:POW:APER:DEF:STAT 0
deactivates the default aperture time of the sensor.
Manual operation:
See
:SENSe<ch>[:POWer]:APERture:TIMe
<ApTime>
Defines the aperture time (size of the acquisition interval) for the corresponding sensor.
SENSe, READ and INITiate Subsystems