![Rohde & Schwarz SMBV100A Скачать руководство пользователя страница 542](http://html1.mh-extra.com/html/rohde-and-schwarz/smbv100a/smbv100a_operating-manual_1477735542.webp)
Remote Control Commands
R&S
®
SMBV100A
527
Operating Manual 1176.8016.02 ─ 17
Figure 7-7: Contents of SICO.txt: first column Sine (I), second column Cosine (Q)
2. Convert the values from the file
SICO.txt
into binary format consisting of 16-bit
signed integer numbers. The numeric range between –1.0 and +1.0 corresponds to
the modulation range of the waveform 16-bit D/A converter of -32767 to +32767.
+1.0 ->
32767 ->
= 0x7FFF
0.0 ->
0 ->
= 0x0000
-1.0 ->
-32767 -> = 0x8001
The
shows the calculation and conversion steps. The highlighted col-
umns contain the resulting I and Q values represented in Little endian format.
Waveform and List Format