![Rohde & Schwarz SMBV100A Скачать руководство пользователя страница 472](http://html1.mh-extra.com/html/rohde-and-schwarz/smbv100a/smbv100a_operating-manual_1477735472.webp)
Instrument Function
R&S
®
SMBV100A
457
Operating Manual 1176.8016.02 ─ 17
Overload
Indicates that the I/Q input is currently overloaded. This indication also appears in the
block diagram close to the I/Q connector of the Baseband Input block.
If overload is indicated either the amplitude of the external signal is too high (full scale
of 0.5 V) and must be reduced or the entered "Peak Level" (in dB full scale) value does
not correspond with the real value and must be corrected. It also can be evaluated
automatically with button "Auto Level Set".
Remote command:
[:SOURce<hw>]:BBIN:OLOad:STATe?
Overload Hold
Indicates an overload since last reset for evaluating the measurement.
The Overload Hold state can be reset via the "Reset" button next to the LED, or is
reset automatically by starting a new measurement ("Auto
Level Set") or by setting
new values (Crest Factor, Peak Level, Level).
Remote command:
[:SOURce<hw>]:BBIN:OLOad:HOLD:STATe?
Reset
Executes a reset of the "Overload Hold" state and LED.
Remote command:
[:SOURce<hw>]:BBIN:OLOad:HOLD:STATe?
Connected Device
Indicates the ID of a connected R&S Instrument or R&S device.
If supported by the transmitter, also the transmitter sample rate is shown.
Note:
The connected instrument is indicated only, if the connection is properly estab-
lished and signal transmission is active.
Remote command:
5.10.2.2
Frequency and Phase Offset
A frequency and a phase offset can be added to the baseband signal. Define the
parameters "BB Input Frequency Offset" and "BB Input Phase Offset" in the "Baseband
In/Out" block menu.
Frequency Offset
Enters the frequency offset for the external baseband signal. It shifts the useful base-
band signal in the center frequency.
The offset affects the signal on the output of the "Baseband In/Out" block.
External Baseband Signal - Baseband Input