Remote Control Commands
R&S
®
SMBV100A
621
Operating Manual 1176.8016.02 ─ 17
Return values:
<Conflict>
0 | 1 | OFF | ON
*RST:
0
Example:
BB:ARB:MCAR:CARR2:CONF?
queries the multi carrier conflict state.
Response:
0
no conflict has occurred.
Usage:
Query only
Manual operation:
See
[:SOURce<hw>]:BB:ARBitrary:MCARrier:CARRier<ch>:DELay
<Delay>
Sets the start delay of the selected carrier.
Parameters:
<Delay>
float
Range:
0 to 1
Increment: 1E-9
*RST:
0
Default unit: s
Example:
BB:ARB:MCAR:CARR15:DEL 5us
sets a start delay of 50 us for carrier 15.
Manual operation:
See
[:SOURce<hw>]:BB:ARBitrary:MCARrier:CARRier<ch>:FILE
<File>
Selects the file with I/Q data to be modulated onto the selected carrier.
Parameters:
<File>
<file name>
Example:
BB:ARB:MCAR:CARR15:FILE "/var/user/IQ_wcdma"
selects file
IQ_wcdma
. The data of the file is modulated onto
carrier 15.
Manual operation:
See
[:SOURce<hw>]:BB:ARBitrary:MCARrier:CARRier<ch>:FREQuency
<Frequency>
Sets or indicates the carrier frequency, depending on the selected carrier frequency
mode.
The carrier frequency can be set in "Arbitrary Carrier frequency" mode. For "Equidis-
tant Carrier Spacing", the carrier spacing is determined automatically.