![Rohde & Schwarz SMBV100A Скачать руководство пользователя страница 776](http://html1.mh-extra.com/html/rohde-and-schwarz/smbv100a/smbv100a_operating-manual_1477735776.webp)
Remote Control Commands
R&S
®
SMBV100A
761
Operating Manual 1176.8016.02 ─ 17
Parameters:
<Stop>
float
Range:
full frequency range
Increment: see the data sheet: resolution of frequency setting
*RST:
100 KHz
Example:
LFO:FREQ:STOP 10 kHz
sets the stop frequency for the LF sweep to 10 kHz.
Manual operation:
See
[:SOURce]:LFOutput[:STATe]
<State>
Activates/deactivates the LF output.
Parameters:
<State>
0 | 1 | OFF | ON
*RST:
0
Example:
LFO ON
activates the LF output. The settings under
LFO:FREQ
and
LFO:SWE
become effective.
Manual operation:
See
[:SOURce<hw>]:LFOutput:SWEep[:FREQuency]:DWELl
<Dwell>
Sets the dwell time for each frequency step of the sweep.
Tip:
It is recommended to switch off the "Display Update" for optimum sweep perform-
ance especially with short dwell times (
Parameters:
<Dwell>
float
Range:
see data sheet: Dwell time setting range
Increment: 100E-6
*RST:
15E-3
Example:
LFO:SWE:DWEL 20 ms
sets a dwell time of 20 ms.
Manual operation:
See
[:SOURce<hw>]:LFOutput:SWEep[:FREQuency]:EXECute
Immediately starts an LF frequency sweep in
.
Example:
LFO:SWE:MODE SING
sets the single cycle mode of the LF sweep.
LFO:SWE:EXEC
starts one cycle of the LF sweep.
Usage:
Event