Digital I/Q Outputs
This subsystem contains the commands for configuring the digital I/Q output. The digi-
tal signal can be output with the aid of a standardized (LVDS) digital user interface.
For information about the required options, see
Chapter 5.8, "Digital I/Q Output Set-
[:SOURce<hw>]:IQ:OUTPut:DIGital:CDEVice?
................................................................. 753
[:SOURce]:IQ:OUTPut:DIGital:OFLow:HOLD:RESet
..........................................................753
[:SOURce]:IQ:OUTPut:DIGital:OFLow:HOLD:STATe?
....................................................... 753
[:SOURce]:IQ:OUTPut:DIGital:OFLow:STATe?
.................................................................754
[:SOURce<hw>]:IQ:OUTPut:DIGital:PON
......................................................................... 754
[:SOURce<hw>]:IQ:OUTPut:DIGital:POWer:LEVel
............................................................ 754
[:SOURce<hw>]:IQ:OUTPut:DIGital:POWer:PEP
.............................................................. 755
[:SOURce<hw>]:IQ:OUTPut:DIGital:POWer:STEP[:INCRement]
.........................................755
[:SOURce<hw>]:IQ:OUTPut:DIGital:POWer:STEP:MODE
..................................................756
[:SOURce<hw>]:IQ:OUTPut:POWer:VIA
.......................................................................... 756
[:SOURce<hw>]:IQ:OUTPut:DIGital:SRATe
......................................................................756
[:SOURce<hw>]:IQ:OUTPut:DIGital:SRATe:SOURce
........................................................ 757
[:SOURce<hw>]:IQ:OUTPut:DIGital:STATe
...................................................................... 757
[:SOURce<hw>]:IQ:OUTPut:DIGital:CDEVice?
Queries the ID of a connected Rohde&Schwarz instrument.
Return values:
<CDevice>
string
Example:
IQ:OUTP:DIG:CDEV?
queries the connected device ID.
Usage:
Query only
Manual operation:
See
"Connected Device - Digital I/Q Out"
[:SOURce]:IQ:OUTPut:DIGital:OFLow:HOLD:RESet
Resets the overflow hold state and LED.
Example:
SOUR:IQ:OUTP:DIG:OFL:HOLD:RESet
resets the overflow hold state.
Usage:
Event
Manual operation:
See
[:SOURce]:IQ:OUTPut:DIGital:OFLow:HOLD:STATe?
Queries an overflow since the last reset.
To reset the overflow hold state, use one of the following:
●
[:SOURce]:IQ:OUTPut:DIGital:OFLow:HOLD:RESet