![Rohde & Schwarz SMBV100A Скачать руководство пользователя страница 438](http://html1.mh-extra.com/html/rohde-and-schwarz/smbv100a/smbv100a_operating-manual_1477735438.webp)
Instrument Function
R&S
®
SMBV100A
423
Operating Manual 1176.8016.02 ─ 17
lowing settings enable switching times of approx. 20 ms for segments with the same
sample rate and approx. 200 ms for segments with different sample rates:
1. "Extended Trigger Mode" = "Next Segment"
2. "Trigger Mode" = "Auto"
3. "Trigger Source" = "Internal"
Flexible Dynamic Switchovers without Signal Interruptions
Testing receivers requires a continuous output of different test signals without interrupt-
ing the signal. The test signals then produce a complex total signal with no signal gaps
on switchover. Control procedures can use a simulated back channel of the receiver
(trigger line or remote control).
Switching times depend on the length of the segment currently being output, since
switchover to the next segment does not take place until the current segment comes to
an end.
1. "Extended Trigger Mode" = "Next Segment Seamless"
2. "Trigger Mode" = "Auto"
3. "Trigger Source" = "Internal or External"
If the waveforms have different sample rates:
4. "Clock Mode" = "Highest" or "User" (when creating the waveform in the Multi Seg-
ment Editor)
5.9.4.4
Multi Carrier Waveforms
Multi carrier waveforms consisting of up to 512 carriers modulated by user-selectable
baseband signals can be created in order to simulate complex multi carrier scenarios
with different baseband signals (e.g. CDMA2000 or 3GPP FDD).
The carriers are equally spaced and centered toward the RF frequency or baseband
DC line, respectively. The carrier spacing is adjustable within the total available base-
band bandwidth of 80 MHz. Each carrier can be separately defined in terms of power,
phase and modulated input signal. Optionally, crest factor optimization can be applied.
Thus, multi carrier waveforms can be very easily configured as broadband test signals
and used for such purposes as transmitter or receiver tests. Even complex multi carrier
scenarios composed of signals from different digital standards can be created and
used for these tests.
Example for the creation of a multi carrier waveform file
1. Configure general settings
2. Configure carrier table
3. Enter file name of multi carrier waveform ("Output File")
4. Save and load multi carrier waveform ("Create" or "Create and Load")
Baseband Signal - Baseband Block