![Rohde & Schwarz SMBV100A Скачать руководство пользователя страница 302](http://html1.mh-extra.com/html/rohde-and-schwarz/smbv100a/smbv100a_operating-manual_1477735302.webp)
Instrument Function
R&S
®
SMBV100A
287
Operating Manual 1176.8016.02 ─ 17
Retrace - RF Level Sweep
Activates that the signal changes to the start level value while it is waiting for the next
trigger event. It allows you to shift down the power during the waiting period.
You can enable this feature, when you are working with sawtooth shapes in sweep
mode "Single" or "External Single", see
Remote command:
[:SOURce<hw>]:SWEep:POWer:RETRace
Step - Level Sweep
Sets the step width for the individual sweep steps. This entry is effective for all sweep
modes.
With the level sweep, the logarithmic step width is a constant fraction of the current
level. This fraction is added to the current level. The logarithmic step width is entered in
dB.
Remote command:
[:SOURce<hw>]:SWEep:POWer:STEP[:LOGarithmic]
Dwell Time - Level Sweep
Enters the dwell time and determines the duration of the individual sweep steps.
RF Block